Elektra  0.8.21
Plugin: dbus

This plugin is a notification plugin, which sends a signal to D-Bus when the key database (KDB) has been modified.

Dependencies

Dbus

A preferred way to interconnect desktop applications and even embedded system applications on mobile devices running Linux is D-Bus. The idea of D-Bus accords to that of Elektra: to provide standards to let software work together more tightly. D-Bus provides a simple and lightweight IPC (Inter-Process Communication) system to be used within desktop systems. Next to RPC (Remote Procedure Call), which is not used in this plugin, it supports signals which can notify an arbitrary number of other applications about changes. Given software like a D-Bus library, notification itself is a rather easy task, but it involves additional library dependences. So it is the perfect task to be implemented as a plugin. The information about the channels to be used can be stored in the global key database.

D-Bus supports a system-wide bus and a session bus. The system configuration can be accessed by each user and the user configuration is limited to a single user. Both buses can immediately be used for the system and user configuration notification updates to get pleasing results. But, there is a problem with the session bus: It is possible within D-Bus that a user starts several sessions. The user configuration should be global to the user and is not aware of these sessions. So if several sessions are started, some of the user's processes will miss notification updates.

The namespaces are mapped to the buses the following way:

Following signal names are used to notify about changes in the Elektra’s KeySet:

Alternatively, (with the option announce=once) only a single message is send:

Usage

The recommended way is to globally mount the plugin:

    kdb global-mount dbus

Alternatively one can mount the plugin additionally to a storage plugin, e.g.:

    kdb mount file.dump / dump dbus

For openicc one would use (mounts with announce=once):

    kdb mount-openicc

Shell

Then we can receive the notification events using:

    dbus-monitor type='signal',interface='org.libelektra',path='/org/libelektra/configuration'

Or via the supplied test program:

    kdb testmod_dbus receive_session

We can trigger a message with:

    kdb set user/dbus/x b

Note that changes in user fire on the dbus session, and changes in namespace system in the dbus system bus. To receive system changes we will use:

    kdb testmod_dbus receive_system
    dbus-monitor --system type='signal',interface='org.libelektra',path='/org/libelektra/configuration'

And then fire it with:

    kdb set system/dbus/y a

C

dbus_bus_add_match (connection, "type='signal',interface='org.libelektra',path='/org/libelektra/configuration'", &error);

See the full example here.

Qt

Here a small example for QDBusConnection:

Place this in your Qt class header:

public slots:
  void configChanged( QString msg );

Put this in your Qt class, e.g. the constructor:

if( QDBusConnection::sessionBus().connect( QString(), "/org/libelektra/configuration", "org.libelektra", QString(),
                                       this, SLOT( configChanged( QString ) )) )
    fprintf(stderr, "=================== Done connect\n" );

Here comes the org.libelektra signals:

void SynnefoApp::configChanged( QString msg )
{
  fprintf( stdout, "config changed: %s\n", msg.toLocal8Bit().data() );
};

Python

In Python the DBus notifications can be used as follows

import dbus
import gobject
gobject.threads_init() # important: initialize threads if gobject main loop is used
from dbus.mainloop.glib import DBusGMainLoop
class DBusTest():
def __init__(self):
DBusGMainLoop(set_as_default=True)
bus = dbus.SystemBus() # may use session bus for user db
bus.add_signal_receiver(self.elektra_dbus_key_changed_cb,
signal_name="KeyChanged",
dbus_interface="org.libelektra",
path="/org/libelektra/configuration")
def elektra_dbus_key_changed_cb(self, key):
print('key changed %s' % key)
test = DBusTest()
loop = gobject.MainLoop()
try:
loop.run()
except KeyboardInterrupt:
loop.quit()

Background

Today, programs are often interconnected in a dense way. Such applications should always be informed when something in their environment changes. For user interactive software, notification about configuration changes is expected. The only alternative is polling, which wastes resources. It additionally is no option for interactive software, where the latency needs to be low. Instead, the software which changes the configuration has to notify all other interested applications that can reread their configuration without significant delay. In Elektra, a notification plugin ensures that a notification is actually sent on each change.

Applications can wait for such a notification with hand-written code. Bindings, however, allow for better integration. It is a common approach for toolkits to provide a main loop. Applications using such toolkits can integrate notification services into this main loop.

The actions that occur in such events are application or toolkit specific because of the non-invasive nature of Elektra. Software reacts in many different ways to update events. Hence, the frequency of update events should be kept at a minimum. Changes are kept atomic with a single attempt to write out configuration. Notification callbacks shall not change configuration because this can lead to a longer chain of unwanted modifications. That might not be true, however, if a programmer of the whole system knows that a chain of reactions will terminate. When doing such event-driven programming, care is needed to avoid infinite loops. Elektra guarantees consistency of the key database even in such cases.